SAV-LDG Remote type electromagnetic flowmeter
The Electromagnetic flowmeter is specifically designed for measuring the flow of conductive liquids, making it a versatile tool widely used in various applications such as water supply, sewage water measurement, and chemical industry processes. Its remote type boasts a high IP protection class, allowing for installation in different locations for both the transmitter and converter, ensuring adaptability to your unique setup.
Choose from multiple output signal options, including pulse, 4-20mA, or RS485 communication, to suit your specific data transmission requirements. With its reliable and precise measurements, this flowmeter is an ideal solution for optimizing flow monitoring processes and achieving accurate results consistently.
Experience the seamless functionality and efficiency of our Electromagnetic flowmeter in your operations, no matter the application. Explore its capabilities today and discover the advantages it brings to your flow measurement needs.
Features
Accuracy: ±0.5% (Flow speed > 1m/s)
Reliably: 0.15%
Theoretical value: Water: Min. 20μS/cm; Other liquid: Min. 5μS/cm
Recommended value: >30μS/cm
Flange: ANSI/JIS/DIN DN15… 1000
Ingress protection: IP68
SPECIFICATIONS
Product | Electromagnetic flow meter |
---|---|
Model | SAV-LDG REMOTE |
Diameter nominal | DN15~DN1200 |
Nominal pressure | DN15 - DN250, PN ≤1.6MPa; DN300 - DN1000, PN ≤1.0MPa; DN1200, PN ≤0.6 MPa; Higher pressure can be customized |
Accuracy | ±0.5% F.S. (Flow speed > 1m/s); ±0.5% F. S. ±2mm/s (Flow speed <1m/s) |
Electrode Material | 316L Stainless Steel, Hastelloy C, Hastelloy B, Ti, Ta, Pt |
Liner material | Neoprene (CR), Polyurethane (PU), PTFE (F4), PFEP (F46), PFA |
Medium temperature | Neoprene: -10…+60℃ Polyurethane: -10…+60℃ PTFE/FEP: -10…+120℃ PFA: -10…+180℃ |
Power supply | 85-245VAC,50/60Hz, 22VDC-26VDC |
Ingress Protection | IP65 for converter, IP68 for sensor |
Product standard | JB/T 9248-1999 Electromagnetic Flow Meter |
Electric Conductivity | Water min.20μS/cm;other medium min.5μS/cm |
Product Standard | JB/T 9248-1999 Electromagnetic Flow Meter |
- Measuring principle
Mag meter works based on Faraday's law, when the liquid goes through the pipe at the flow rate of v with a diameter D, within which a magnetic flux density of B is created by an exciting coil, the following electromotive E is generated in proportion to flow speed v:
E=K×B×V×D
Where:
E-Induced electromotive force
K-Meter constant
B-Magnetic induction density
V-Average flow speed in cross-section of measuring tube
D-Inner diameter of measuring tube New Paragraph