SUP-TRC 400 Residual chlorine meter


SUP-TRC 400 Residual chlorine meter has a built-in sensor, which has the characteristics of high measurement accuracy, fast response time and low maintenance cost.


Features

Measure range:

Residual chlorine: (0~5) mg/L

Temperature: (0.1~40.0)℃

Load Resistance: ≤750Ω

Power supply: 220VAC

Communication : MODBUS RS485

SPECIFICATIONS

Product Residual chlorine meter
Model SAV-TRC 400
Measure range Residual chlorine: (0~5) mg/L Temperature: (0.1~40.0)℃
Display 7 inch touch screen
Protective box size Dimensions: 400mm×300mm×200mm Window size: 155mm×87mm
Transmit output (4~20)mA (optional)
Load resistance ≤750Ω
Communication RS485, Modbus
Environmental humidity ≤95% no condensate
Power supply 220VAC
Ingress protection IP43


SUP-ERC 400 Residual chlorine sensor

Measurement content HCLO、CLO2
Measuring system Microelectronics MEMS technology, special membrane structure
Measure range (0~5)mg/L
Accuracy When ≤0.1mg/L, the absolute error is ±0.01mg/L; When ≥0.1mg/L, ±5% of the measured value or ±0.02mg/L (whichever is greater)
Resolution 0.01
Polarization time When using for the first time, first pass water for 2 hours in chlorinated water, and then power on for half an hour.
Response time Less than 30s after polarization is completed
Minimum conductivity ≥100us/cm, can not be used for ultrapure water
Operating temperature (0~40)℃ (non-condensing)
Temperature compensation Pt1000 with built-in integrated automatic compensation
Max pressure 4bar
Recommended flow rate ≥0.03m/s in flow cell
pH range (5~9) pH, below 5 will damage the membrane head
Maximum chlorine concentration ≥5ppm
Power supply Standard 24V DC±2V; optional 12V DC±2V
Power consumption 1.56W
Digital communication MODBUS RS485
Cable length Standard 3 meters, others can be customized
Probe weight 210g
Thread size NPT 3/4
Connection method 5-pin waterproof aviation plug
Moisture-proof material PVC and Viton® O-ring seals

Introduction

​​​​​​The residual chlorine meter has a built-in sensor, which has the characteristics of high measurement accuracy, fast response time and low maintenance cost. The residual chlorine meter outputs 4~20mA standard signal and RS485 signal, which can be connected to various regulators, and can be connected to two-position regulators, time proportional regulators, non-linear regulators and classic PID regulators according to requirements, which can be combined into various types. Residual chlorine control system.


Features

  1. The electrode measurement is accurate and the response speed is fast
  2. LCD with backlight, easy and intuitive operation
  3. With automatic temperature compensation, pH manual compensation function
  4. Restore factory function to avoid data loss by misoperation
  5. Isolated 4-20mA standard signal can realize signal remote transmission
  6. Range can be switched manually
  7. A variety of calibration methods are convenient for on-site adjustment





Contact Us